Fonctionnalités prises en charge
- Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.
Domaines d’utilisation
- Compteur avant réseau
- Production solaire
- Batterie
Paramètres
| Nom | Description | Valeur | Niveau |
|---|---|---|---|
host | IP address or hostname | facultatif | |
capacity [kWh] | Battery capacity | facultatif | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facultatif | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | facultatif | |
password | Password Service account password | avancé | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avancé | |
battery | Controllable battery component active battery control (REST/JSON Write Access) | avancé | |
watchdog | FEMS/OpenEMS battery control API timeout FEMS/OpenEMS standard 60s | avancé | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | avancé | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | avancé | |
cache | Cache Time interval for data refresh | avancé |
Exemple de configuration pour evcc.yaml
Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.
meters: - name: my_grid type: template template: openems usage: grid host: 192.0.2.2 # IP address or hostname password: user # Password, Service account password (optional) cache: 1s # Cache, Time interval for data refresh (optional)meters: - name: my_pv type: template template: openems usage: pv host: 192.0.2.2 # IP address or hostname password: user # Password, Service account password (optional) maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional cache: 1s # Cache, Time interval for data refresh (optional)meters: - name: my_battery type: template template: openems usage: battery host: 192.0.2.2 # IP address or hostname capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) password: user # Password, Service account password (optional) battery: ess0 # Controllable battery component, active battery control (REST/JSON Write Access) (optional) watchdog: 60s # FEMS/OpenEMS battery control API timeout, FEMS/OpenEMS standard 60s (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional) cache: 1s # Cache, Time interval for data refresh (optional)