Solar API should only be used as fallback. Integration via Modbus is preferred.

Username and password are only required for active battery control.

Attention: Active battery control should only be used if no other settings for time-dependent battery control were made in the inverter configuration under "Energy Management" - "Battery Management", as existing settings will be overwritten. Choose corresponding configuration URI!

Fonctionnalités prises en charge

  • Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie

Paramètres

NomDescriptionValeurNiveau
hostIP address or hostname
Exemple: 192.0.2.2
facultatif
userUsername (for active battery control)

e.g. email address, user id, etc.

Par défaut: customer
facultatif
passwordPassword (for active battery control)

Service account password

facultatif
capacity [kWh]Battery capacity
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Par défaut: 100
Exemple: 95
facultatif
batteryconfiguriBattery configuration URI

Firmware starting with 1.36.5-1 requires /api/config.

Par défaut: /config
avancé
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avancé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avancé
cacheCache

Time interval for data refresh

Par défaut: 1s
Exemple: 5m
avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: fronius-solarapi-v1
usage: grid
host: 192.0.2.2 # IP address or hostname
user: customer # Username (for active battery control), e.g. email address, user id, etc. (optional)
password: # Password (for active battery control), Service account password (optional)
batteryconfiguri: /config # Battery configuration URI, Firmware starting with 1.36.5-1 requires /api/config. [/config, /api/config] (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: fronius-solarapi-v1
usage: pv
host: 192.0.2.2 # IP address or hostname
user: customer # Username (for active battery control), e.g. email address, user id, etc. (optional)
password: # Password (for active battery control), Service account password (optional)
batteryconfiguri: /config # Battery configuration URI, Firmware starting with 1.36.5-1 requires /api/config. [/config, /api/config] (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: fronius-solarapi-v1
usage: battery
host: 192.0.2.2 # IP address or hostname
user: customer # Username (for active battery control), e.g. email address, user id, etc. (optional)
password: # Password (for active battery control), Service account password (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
batteryconfiguri: /config # Battery configuration URI, Firmware starting with 1.36.5-1 requires /api/config. [/config, /api/config] (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)