Aller au contenu
recharge intelligente

ioBroker

The rest-api adapter (not simple-api) must be installed on the ioBroker instance being used. It must be configured as an extension of a web adapter. Authentication can only be performed using basic authentication. If no password is provided, no authentication will be performed. When specifying the entities for the individual measured values, ensure that they are correctly URL-encoded. For example, shelly.0.SHEM-3#8CAAB561991E#1.Total.ConsumedPower becomes shelly.0.SHEM-3%238CAAB561991E%231.Total.ConsumedPower

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie
  • Compteur du chargeur

Paramètres

NomDescriptionValeurNiveau
uriThe full uri of the host to query

HTTP(S) address

Exemple: https://iobroker.homelab.lan:8082
facultatif
userUsername

e.g. email address, user id, etc.

facultatif
passwordPassword

Service account password

facultatif
power [W]Powerfacultatif
soc [%]State of Chargefacultatif
capacity [kWh]Battery capacity
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Par défaut: 100
Exemple: 95
facultatif
cacheCache

Time interval for data refresh

Exemple: 5m
avancé
energy [kWh]Meter readingavancé
currentL1 [A]L1 currentavancé
currentL2 [A]L2 currentavancé
currentL3 [A]L3 currentavancé
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avancé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avancé
maxacpower [W]Maximum AC power of the hybrid inverter
Par défaut: 0
Exemple: 5000
avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: iobroker
usage: grid
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional
meters:
- name: my_pv
type: template
template: iobroker
usage: pv
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
meters:
- name: my_battery
type: template
template: iobroker
usage: battery
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
meters:
- name: my_charger
type: template
template: iobroker
usage: charge
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional