OpenEMS REST-API

License notice:

For active battery control on FENECON FEMS systems, a commercial license (FEMS App REST/JSON Write Access) is required.

FEMS documentation:
OpenEMS documentation:

Fonctionnalités prises en charge

  • Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie

Paramètres

NomDescriptionValeurNiveau
hostIP address or hostname
Exemple: 192.0.2.2
facultatif
capacity [kWh]Battery capacity
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Par défaut: 100
Exemple: 95
facultatif
passwordPassword

Service account password

Par défaut: user
avancé
maxacpower [W]Maximum AC power of the hybrid inverter
Par défaut: 0
Exemple: 5000
avancé
batteryControllable battery component

active battery control (REST/JSON Write Access)

Exemple: ess0
avancé
watchdogFEMS/OpenEMS battery control API timeout

FEMS/OpenEMS standard 60s

Par défaut: 60s
avancé
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avancé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avancé
cacheCache

Time interval for data refresh

Par défaut: 1s
Exemple: 5m
avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: openems
usage: grid
host: 192.0.2.2 # IP address or hostname
password: user # Password, Service account password (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: openems
usage: pv
host: 192.0.2.2 # IP address or hostname
password: user # Password, Service account password (optional)
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: openems
usage: battery
host: 192.0.2.2 # IP address or hostname
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
password: user # Password, Service account password (optional)
battery: ess0 # Controllable battery component, active battery control (REST/JSON Write Access) (optional)
watchdog: 60s # FEMS/OpenEMS battery control API timeout, FEMS/OpenEMS standard 60s (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)