RCT Power
Fonctionnalités prises en charge
- Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.
- Bridable: La production de l’onduleur peut être réduite (p. ex. § 9 EEG). Voir Limite externe.
Domaines d’utilisation
- Compteur avant réseau
- Production solaire
- Batterie
Paramètres
| Nom | Description | Valeur | Niveau |
|---|---|---|---|
host | IP address or hostname | facultatif | |
port | Port | facultatif | |
capacity [kWh] | Battery capacity | facultatif | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facultatif | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | facultatif | |
capacity2 [kWh] | Battery capacity of the second battery | facultatif | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avancé | |
externalpower | External power Query external power of all devices connected to S0 | avancé | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | avancé | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | avancé | |
cache | Cache Time interval for data refresh | avancé |
Exemple de configuration pour evcc.yaml
Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.
meters: - name: my_grid type: template template: rct-power usage: grid host: 192.0.2.2 # IP address or hostname port: 8899 # Port cache: 30s # Cache, Time interval for data refresh (optional)meters: - name: my_pv type: template template: rct-power usage: pv host: 192.0.2.2 # IP address or hostname port: 8899 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional externalpower: # External power, Query external power of all devices connected to S0 (optional) cache: 30s # Cache, Time interval for data refresh (optional)meters: - name: my_battery type: template template: rct-power usage: battery host: 192.0.2.2 # IP address or hostname port: 8899 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 7 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 97 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) capacity2: 50 # Battery capacity of the second battery (kWh), optional maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional) cache: 30s # Cache, Time interval for data refresh (optional)