In the web interface of the SMA Data Manager you need to activate "Modbus Server activated" in the section "External communication".

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie

Paramètres

NomDescriptionValeurNiveau
idID Modbus
Par défaut: 1
intobligatoire
hostAdresse IP ou nom d’hôte
Exemple: 192.0.2.2
obligatoire
portPort
Par défaut: 502
intobligatoire
capacity [kWh]Battery capacity
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Par défaut: 100
Exemple: 95
facultatif
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avancé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: sma-data-manager
usage: grid
# Modbus TCP
modbus: tcpip
id: 2
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: sma-data-manager
usage: pv
# Modbus TCP
modbus: tcpip
id: 2
host: # Hostname
port: 502 # Port
meters:
- name: my_battery
type: template
template: sma-data-manager
usage: battery
# Modbus TCP
modbus: tcpip
id: 2
host: # Hostname
port: 502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)