SunEnergyXT SunEnergyXT 500 / 500 PRO

The battery's local mode must be enabled in the manufacturer's app. Furthermore, the device's IP address must be set to a fixed, permanent IP address in the router. An external meter (e.g., Shelly) measuring the grid connection point must be connected to the battery via the manufacturer's app. It is required for the grid usage, and also for the battery usage, because the normal battery mode enables the device's zero feed-in regulation, which reads this meter.

Fonctionnalités prises en charge

  • Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie

Paramètres

NomDescriptionValeurNiveau
modelModel

standard for the SunEnergyXT 500, pro for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W).

facultatif
hostIP address or hostname
Exemple: 192.0.2.2
facultatif
capacity [kWh]Battery capacity

Total storage capacity: head unit 5 kWh, each extension pack adds 5 kWh. So 5 (head unit only), 10 (+1 extension) or 15 (+2 extensions). The number of detected battery packs is reported in the ON field of /read.

Par défaut: 5
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Par défaut: 100
Exemple: 95
facultatif
maxacpower [W]Maximum AC power of the hybrid inverter
Par défaut: 0
Exemple: 5000
avancé
maxchargepower [W]Maximum charge power

For forced charging of the battery.

Par défaut: 2400
avancé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avancé
cacheCache

Time interval for data refresh

Par défaut: 2s
Exemple: 5m
avancé
timeoutTimeout
Par défaut: 10s
Exemple: 10s
avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: sunenergyxt-500
usage: grid
model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro]
host: 192.0.2.2 # IP address or hostname
cache: 2s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_pv
type: template
template: sunenergyxt-500
usage: pv
model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro]
host: 192.0.2.2 # IP address or hostname
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
cache: 2s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_battery
type: template
template: sunenergyxt-500
usage: battery
model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro]
host: 192.0.2.2 # IP address or hostname
capacity: 5 # Battery capacity (kWh), Total storage capacity: head unit 5 kWh, each extension pack adds 5 kWh. So 5 (head unit only), 10 (+1 extension) or 15 (+2 extensions). The number of detected battery packs is reported in the `ON` field of `/read`. (optional)
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: 2400 # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 2s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional