The 'Modbus TCP Server' must be enabled. The setting 'Register Address Set' must NOT be set to 'Phoenix' or 'TQ-DM100'. Use the third selection labeled 'Ebee', 'Bender', 'MENNEKES' etc. Set 'Allow UID Disclose' to On.

Firmware 5.33 or higher is required for phase switching (if supported by the model). The 'SEMP interface' must be enabled, the 'SEMP Charging Mode' must be set to 'Surplus Charging'. Set 'Software function to use phase switching' to SEMP.

For charging stations with two charging points (e.g. AMEDIO, Twincharge), each charging point must be configured separately. Set charging point 1 to Port 502 and charging point 2 to Port 503.

Fonctionnalités prises en charge

Paramètres

NomDescriptionValeurNiveau
idID Modbus
Par défaut: 1
intobligatoire
hostAdresse IP ou nom d’hôte
Exemple: 192.0.2.2
obligatoire
portPort
Par défaut: 502
intobligatoire
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

chargers:
- name: my_charger
type: template
template: bender-cc
# Modbus TCP
modbus: tcpip
id: 255
host: # Hostname
port: 502 # Port