Modbus digital input (Discrete Input)

Cette page affiche la version nightly. Il n’existe pas encore de version stable.

Connect the relay contacts of the control box to the digital inputs of the module. The module must provide the inputs as discrete inputs (function code 02), a closed contact reads as active.

Paramètres

NomDescriptionValeurNiveau
idID Modbus
Par défaut: 1
intobligatoire
hostAdresse IP ou nom d’hôte
Exemple: 192.0.2.2
obligatoire
portPort
Par défaut: 502
intobligatoire
maxconsumptionpower [W]Guaranteed minimum power (Pmin)

Power limit applied to the root circuit while the limit is active.

facultatif
w4inputW4 input

Digital input number for the W4 signal (Dimmer for controllable loads), counting from 1 (first input = 1)

Par défaut: 1
facultatif
w3inputW3 input

Digital input number for the W3 signal (Zero export, 0%), counting from 1 (first input = 1)

Par défaut: 2
facultatif
productionnominalmax [Wp]Installed generator power

Rated generator/module power of the installation (reference value according to § 9 EEG).

facultatif
s1inputS1 input

Digital input number for the S1 signal (60% export power limit), counting from 1 (first input = 1)

Exemple: 3
facultatif
s2inputS2 input

Digital input number for the S2 signal (30% export power limit), counting from 1 (first input = 1)

Exemple: 4
facultatif
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

hems:
type: template
template: fnn-modbus
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
maxconsumptionpower: # Guaranteed minimum power (Pmin) (W), Power limit applied to the root circuit while the limit is active.
w4input: 1 # W4 input, Digital input number for the W4 signal (Dimmer for controllable loads), counting from 1 (first input = 1)
w3input: 2 # W3 input, Digital input number for the W3 signal (Zero export, 0%), counting from 1 (first input = 1)
productionnominalmax: # Installed generator power (Wp), Rated generator/module power of the installation (reference value according to § 9 EEG). (optional)
s1input: 3 # S1 input, Digital input number for the S1 signal (60% export power limit), counting from 1 (first input = 1) (optional)
s2input: 4 # S2 input, Digital input number for the S2 signal (30% export power limit), counting from 1 (first input = 1) (optional)