FoxESS H3-Pro/Smart Series Hybrid Inverter
Fonctionnalités prises en charge
- Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.
Domaines d’utilisation
- Compteur avant réseau
- Production solaire
- Batterie
Paramètres
| Nom | Description | Valeur | Niveau |
|---|---|---|---|
id | ID Modbus | int | obligatoire |
device | Nom du périphérique Adaptateur USB-RS485 | obligatoire | |
baudrate | Débit en bauds | obligatoire | |
comset | ComSet Paramètre de communication de l’adaptateur | obligatoire | |
host | Adresse IP ou nom d’hôte | obligatoire | |
port | Port | int | obligatoire |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | facultatif | |
maxdischargecurrent | Max Discharge Current Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3). | facultatif | |
capacity [kWh] | Battery capacity | facultatif | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facultatif | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | facultatif | |
maxchargecurrent | Max Charge Current Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart. | facultatif | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avancé | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | avancé |
Exemple de configuration pour evcc.yaml
Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.
meters: - name: my_grid type: template template: fox-ess-h3-smart usage: grid
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 247 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 247 host: # Hostname port: 502 # Port
# Modbus TCP modbus: tcpip id: 247 host: # Hostname port: 502 # Port maxdischargecurrent: # Max Discharge Current, Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3). maxchargecurrent: 50 # Max Charge Current, Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart. (optional)meters: - name: my_pv type: template template: fox-ess-h3-smart usage: pv
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 247 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 247 host: # Hostname port: 502 # Port
# Modbus TCP modbus: tcpip id: 247 host: # Hostname port: 502 # Port maxdischargecurrent: # Max Discharge Current, Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3). maxchargecurrent: 50 # Max Charge Current, Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart. (optional) maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: fox-ess-h3-smart usage: battery
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 247 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 247 host: # Hostname port: 502 # Port
# Modbus TCP modbus: tcpip id: 247 host: # Hostname port: 502 # Port maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. maxdischargecurrent: # Max Discharge Current, Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3). capacity: 50 # Battery capacity (kWh), optional minsoc: 10 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) maxchargecurrent: 50 # Max Charge Current, Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)