Roche Energy REL261
AC-coupled commercial storage cabinet (261 kWh, 125 kW) with integrated PCS. Measurements only, no battery control.
Modbus TCP must be enabled in the cabinet's HMI under "Remote Management". Power and SoC are served on different Modbus IDs: PCS (ID 2) and BMS (ID 34).
Power (register 30135) mirrors the setpoint applied by the PCS and is not an independent measurement. If the cabinet is controlled externally and does not follow the command (e.g. during a PCS fault), the value deviates from the actual power.
Domaines d’utilisation
- Batterie
Paramètres
| Nom | Description | Valeur | Niveau |
|---|---|---|---|
host | IP address or hostname | facultatif | |
port | Port | facultatif | |
capacity [kWh] | Battery capacity | facultatif |
Exemple de configuration pour evcc.yaml
Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.
meters: - name: my_battery type: template template: roche-energy-rel261 usage: battery host: 192.0.2.2 # IP address or hostname port: 502 # Port, optional capacity: 50 # Battery capacity (kWh), optional