Sigenergy Sigen Hybrid
Modbus TCP must be enabled in the configuration app with installer rights. This option is not available in the mySigen app for customers.
Fonctionnalités prises en charge
- Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.
Domaines d’utilisation
- Compteur avant réseau
- Production solaire
- Batterie
Paramètres
| Nom | Description | Valeur | Niveau |
|---|---|---|---|
id | ID Modbus | int | obligatoire |
host | Adresse IP ou nom d’hôte | obligatoire | |
port | Port | int | obligatoire |
capacity [kWh] | Battery capacity | facultatif | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facultatif | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | facultatif | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avancé | |
gateway | Sigen Energy Gateway installed Uses the "Backup SoC" register (40046) instead of "Discharge Cut-Off SoC" (40048) to block discharge. This keeps the house powered during a grid outage. | avancé | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | avancé | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | avancé |
Exemple de configuration pour evcc.yaml
Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.
meters: - name: my_grid type: template template: sigenergy usage: grid
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: sigenergy usage: pv
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: sigenergy usage: battery
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) gateway: false # Sigen Energy Gateway installed, Uses the "Backup SoC" register (40046) instead of "Discharge Cut-Off SoC" (40048) to block discharge. This keeps the house powered during a grid outage. (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)