Aller au contenu
recharge intelligente

Tasmota SML IR-reader for smartmeters e.g. Hichi

Cette page affiche la version nightly. Passez à la version stable.

To be able to read the values of the smart meter for evcc correctly, the IR reader script must be changed so that the following JSON tags are generated:

  • SML as the group name of the read parameters
  • Total_in for the total consumption in KWh (4 decimal places)
  • Total_out for the total feed-in in KWh (4 decimal places)
  • Power_curr for the current consumption or the current feed-in in W (0 decimal places) As an option, phase values are also supported.
  • power_l1, power_l2, power_l3 for the power of the individual phases in W (0 decimal places)
  • voltage_l1, voltage_l2, voltage_l3 for the voltage of the individual phases in V (4 decimal places)
  • current_l1, current_l2, current_l3 for the current of the individual phases in A (4 decimal places)

A corresponding IR reader script looks like this:

>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,SML
1,77070100010800ff@1000,Gesamtverbrauch,KWh,Total_in,4
1,77070100020800ff@1000,Gesamteinspeisung,KWh,Total_out,4
1,77070100100700ff@1,Verbrauch,W,Power_curr,0
1,77070100600100ff@#,Zählernummer,,Meter_Id,0
# Optional
1,77070100240700ff@1,Leistung_L1,W,power_l1,0
1,77070100380700ff@1,Leistung_L2,W,power_l2,0
1,770701004c0700ff@1,Leistung_L3,W,power_l3,0
1,77070100200700ff@1,Spannung L1,V,voltage_l1,4
1,77070100340700ff@1,Spannung L2,V,voltage_l2,4
1,77070100480700ff@1,Spannung L3,V,voltage_l3,4
1,770701001f0700ff@1,Strom L1,A,current_l1,4
1,77070100330700ff@1,Strom L2,A,current_l2,4
1,77070100470700ff@1,Strom L3,A,current_l3,4
#

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie
  • Compteur du chargeur

Paramètres

NomDescriptionValeurNiveau
hostIP address or hostname
Exemple: 192.0.2.2
facultatif
userUsername

admin is default

facultatif
passwordPassword

Service account password

facultatif
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: tasmota-sml
usage: grid
host: 192.0.2.2 # IP address or hostname
user: # Username, admin is default (optional)
password: # Password, Service account password (optional)
meters:
- name: my_pv
type: template
template: tasmota-sml
usage: pv
host: 192.0.2.2 # IP address or hostname
user: # Username, admin is default (optional)
password: # Password, Service account password (optional)
meters:
- name: my_battery
type: template
template: tasmota-sml
usage: battery
host: 192.0.2.2 # IP address or hostname
user: # Username, admin is default (optional)
password: # Password, Service account password (optional)
meters:
- name: my_charger
type: template
template: tasmota-sml
usage: charge
host: 192.0.2.2 # IP address or hostname
user: # Username, admin is default (optional)
password: # Password, Service account password (optional)