Tesla Powerwall (pypowerwall-server)

Cette page affiche la version nightly. Il n’existe pas encore de version stable.

Uses pypowerwall-server as backend. Reads come from its proxy API, battery control uses its authenticated /control/* routes. For battery control, PW_CONTROL_SECRET must be set on the server; reserve_hold requires pypowerwall-server v0.10.0 or later. Since pypowerwall-server v0.14.0 the server can optionally serve HTTPS on port 8775. Without a TLS reverse proxy or the HTTPS listener it stays plain HTTP; with controlSecret, prefer HTTPS or a trusted network.

Fonctionnalités prises en charge

  • Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie

Paramètres

NomDescriptionValeurNiveau
hostIP address or hostname
Exemple: 192.0.2.2
facultatif
portPort
Par défaut: 8675
facultatif
capacity [kWh]Battery capacity
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Par défaut: 100
Exemple: 95
facultatif
schemaSchema

Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener.

Par défaut: http
avancé
insecureAccept self-signed certificatesavancé
cacheCache

Time interval for data refresh

Par défaut: 1s
Exemple: 5m
avancé
controlSecretControl secret

Value of PW_CONTROL_SECRET. Required for battery control, omit for read-only use.

avancé
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avancé
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: tesla-powerwall-pypowerwall-server
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 8675 # Port, optional
schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional)
insecure: # Accept self-signed certificates, optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: tesla-powerwall-pypowerwall-server
usage: pv
host: 192.0.2.2 # IP address or hostname
port: 8675 # Port, optional
schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional)
insecure: # Accept self-signed certificates, optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: tesla-powerwall-pypowerwall-server
usage: battery
host: 192.0.2.2 # IP address or hostname
port: 8675 # Port, optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional)
insecure: # Accept self-signed certificates, optional
cache: 1s # Cache, Time interval for data refresh (optional)
controlSecret: # Control secret, Value of PW_CONTROL_SECRET. Required for battery control, omit for read-only use. (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)