Gå til indhold
smart opladning

Sonnen sonnenBatterie

For active battery control, the "JSON Write API" must be activated via the sonnenBatterie web interface (under Software-Integration) and the API token generated there must be entered in the battery configuration under token. The two operating modes supported for the sonnenBatterie are "self-consumption" (default) and "time-of-use". The mode can be adapted to the configuration of the sonnenBatterie via the 'defaultmode' parameter. The power for grid charging can be adapted to the inverter power of the sonnenBatterie via the maxchargepower parameter.

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
hostIP address or hostname
Eksempel: 192.0.2.2
valgfri
defaultmodeDefault mode for battery control

Inverter falls back to this mode after charging the battery or after stopping discharge.

Standard: self-consumption
valgfri
portPort
Standard: 8080
valgfri
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standard: 100
Eksempel: 95
valgfri
tokenToken

API Token (required for active battery control)

valgfri
maxchargepower [W]Maximum charge power

For forced charging of the battery.

Standard: 3300
avanceret
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanceret
cacheCache

Time interval for data refresh

Standard: 1s
Eksempel: 5m
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: sonnenbatterie
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 8080 # Port, optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: sonnenbatterie
usage: pv
host: 192.0.2.2 # IP address or hostname
port: 8080 # Port, optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: sonnenbatterie
usage: battery
host: 192.0.2.2 # IP address or hostname
defaultmode: self-consumption # Default mode for battery control, Inverter falls back to this mode after charging the battery or after stopping discharge. [self-consumption, time-of-use]
port: 8080 # Port, optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
token: # Token, API Token (required for active battery control) (optional)
maxchargepower: 3300 # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)