Gå til indhold
smart opladning

1SINQ OneKey

Denne side viser nightly-versionen. Skift til release-versionen.

OneKey heating controller with evcc integration enabled. The heat pump is controlled via SG Ready states (1=dim, 2=normal, 3=boost). The device's energy manager must run in SG Ready mode with evcc selected as the SG Ready source. When evcc runs on the OneKey device itself the broker is localhost.

Understøttede funktioner

  • Indbygget måler: Understøttelse af en integreret måler.
  • Kan nedreguleres: Effektforbruget kan reduceres (f.eks. § 14a EnWG). Se Ekstern grænse.

Parametre

NavnBeskrivelseVærdiNiveau
hostIP address or hostname

IP address or hostname of the MQTT broker

Eksempel: 192.0.2.2
valgfri
portPort

MQTT broker port

Standard: 1883
valgfri
topicBase topic of the OneKey device

Topic (omit leading /)

Standard: onekey
valgfri
timeoutTimeout

When a reading counts as stale — default 90 s, three times the device's 30 s heartbeat

Standard: 90s
Eksempel: 10s
valgfri
userUsername

e.g. email address, user id, etc.

avanceret
passwordPassword

Service account password

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

chargers:
- name: my_heating
type: template
template: onekey
host: 192.0.2.2 # IP address or hostname, IP address or hostname of the MQTT broker
port: 1883 # Port, MQTT broker port (optional)
topic: onekey # Base topic of the OneKey device, Topic (omit leading /) (optional)
timeout: 90s # Timeout, When a reading counts as stale — default 90 s, three times the device's 30 s heartbeat (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)