Fronius Verto Plus

Denne side viser nightly-versionen. Skift til release-versionen.

Meter address of primary or secondary meters: on the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201).

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
  • Kan begrænses: Inverterens produktion kan reduceres (f.eks. § 9 EEG). Se Ekstern grænse.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
idModbus-ID
Standard: 1
intpåkrævet
hostIP-adresse eller værtsnavn
Eksempel: 192.0.2.2
påkrævet
portPort
Standard: 502
intpåkrævet
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Standard: 100
Eksempel: 95
valgfri
maxchargerate [%]Maximum charge rate

For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter.

Standard: 100
avanceret
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avanceret
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: fronius-vertoplus
usage: grid
# Modbus TCP
modbus: tcpip
id: 200
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: fronius-vertoplus
usage: pv
# Modbus TCP
modbus: tcpip
id: 200
host: # Hostname
port: 502 # Port
meters:
- name: my_battery
type: template
template: fronius-vertoplus
usage: battery
# Modbus TCP
modbus: tcpip
id: 200
host: # Hostname
port: 502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
maxchargerate: 100 # Maximum charge rate (%), For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)