Kostal Plenticore Hybrid

Denne side viser nightly-versionen. Skift til release-versionen.

Compatible with various inverter generations (G1/G2/G3). For active battery control, the feature external battery control via Modbus must be activated using installer access.

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
  • Kan begrænses: Inverterens produktion kan reduceres (f.eks. § 9 EEG). Se Ekstern grænse.

Anvendelsesområder

  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
idModbus-ID
Standard: 1
intpåkrævet
hostIP-adresse eller værtsnavn
Eksempel: 192.0.2.2
påkrævet
portPort
Standard: 502
intpåkrævet
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Standard: 100
Eksempel: 95
valgfri
endiannessEndianness (Little/Big)
Standard: little
avanceret
maxacpower [W]Maximum AC power of the hybrid inverter
Standard: 0
Eksempel: 5000
avanceret
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avanceret
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanceret
watchdogWatchdog
Standard: 60s
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_pv
type: template
template: kostal-plenticore-gen2
usage: pv
# Modbus TCP
modbus: tcpip
id: 71
host: # Hostname
port: 1502 # Port
endianness: little # Endianness (Little/Big), [little, big] (optional)
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
watchdog: 60s # Watchdog, optional
meters:
- name: my_battery
type: template
template: kostal-plenticore-gen2
usage: battery
# Modbus TCP
modbus: tcpip
id: 71
host: # Hostname
port: 1502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
endianness: little # Endianness (Little/Big), [little, big] (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
watchdog: 60s # Watchdog, optional