Kostal Plenticore Hybrid
Compatible with various inverter generations (G1/G2/G3). For active battery control, the feature external battery control via Modbus must be activated using installer access.
Understøttede funktioner
- Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
- Kan begrænses: Inverterens produktion kan reduceres (f.eks. § 9 EEG). Se Ekstern grænse.
Anvendelsesområder
- Solproduktion
- Batteri
Parametre
| Navn | Beskrivelse | Værdi | Niveau |
|---|---|---|---|
id | Modbus-ID | int | påkrævet |
host | IP-adresse eller værtsnavn | påkrævet | |
port | Port | int | påkrævet |
capacity [kWh] | Battery capacity | valgfri | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | valgfri | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | valgfri | |
endianness | Endianness (Little/Big) | avanceret | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avanceret | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | avanceret | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | avanceret | |
watchdog | Watchdog | avanceret |
Konfigurationseksempel til evcc.yaml
Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.
meters: - name: my_pv type: template template: kostal-plenticore-gen2 usage: pv
# Modbus TCP modbus: tcpip id: 71 host: # Hostname port: 1502 # Port endianness: little # Endianness (Little/Big), [little, big] (optional) maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional watchdog: 60s # Watchdog, optionalmeters: - name: my_battery type: template template: kostal-plenticore-gen2 usage: battery
# Modbus TCP modbus: tcpip id: 71 host: # Hostname port: 1502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) endianness: little # Endianness (Little/Big), [little, big] (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional) watchdog: 60s # Watchdog, optional