RCT Power

Denne side viser nightly-versionen. Skift til release-versionen.

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
  • Kan begrænses: Inverterens produktion kan reduceres (f.eks. § 9 EEG). Se Ekstern grænse.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
hostIP address or hostname
Eksempel: 192.0.2.2
valgfri
portPort
Standard: 8899
valgfri
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 7
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Standard: 97
Eksempel: 95
valgfri
capacity2 [kWh]Battery capacity of the second battery
Eksempel: 50
valgfri
maxacpower [W]Maximum AC power of the hybrid inverter
Standard: 0
Eksempel: 5000
avanceret
externalpowerExternal power

Query external power of all devices connected to S0

avanceret
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avanceret
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanceret
cacheCache

Time interval for data refresh

Standard: 30s
Eksempel: 5m
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: rct-power
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 8899 # Port
cache: 30s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: rct-power
usage: pv
host: 192.0.2.2 # IP address or hostname
port: 8899 # Port
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
externalpower: # External power, Query external power of all devices connected to S0 (optional)
cache: 30s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: rct-power
usage: battery
host: 192.0.2.2 # IP address or hostname
port: 8899 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 7 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 97 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
capacity2: 50 # Battery capacity of the second battery (kWh), optional
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
cache: 30s # Cache, Time interval for data refresh (optional)