The Solax hybrid inverter has to be registered in the SolaxCloud.

Attention: Values can only be fetched every 150s and then also can be 5 minutes old. Charging by PV will not be optimal because of this! Only use as fallback if no local access is available.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
tokenidSolaxCloud TokenID

solaxcloud.com -> Support -> Third-party Ecology (old site) or Service -> API (new site), enter the value of tokenID here (Example: 20241028488283838)

valgfri
serialSerial number

solaxcloud.com -> Device -> Inverter (new site) or Support (old site), use the registration number

valgfri
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Standard: 100
Eksempel: 95
valgfri
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avanceret
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanceret
cacheCache

Time interval for data refresh

Standard: 1s
Eksempel: 5m
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: solax-hybrid-cloud
usage: grid
tokenid: # SolaxCloud TokenID, [solaxcloud.com](https://www.solaxcloud.com/) -> Support -> Third-party Ecology (old site) or Service -> API (new site), enter the value of `tokenID` here (Example: 20241028488283838)
serial: # Serial number, [solaxcloud.com](https://www.solaxcloud.com/) -> Device -> Inverter (new site) or Support (old site), use the registration number
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: solax-hybrid-cloud
usage: pv
tokenid: # SolaxCloud TokenID, [solaxcloud.com](https://www.solaxcloud.com/) -> Support -> Third-party Ecology (old site) or Service -> API (new site), enter the value of `tokenID` here (Example: 20241028488283838)
serial: # Serial number, [solaxcloud.com](https://www.solaxcloud.com/) -> Device -> Inverter (new site) or Support (old site), use the registration number
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: solax-hybrid-cloud
usage: battery
tokenid: # SolaxCloud TokenID, [solaxcloud.com](https://www.solaxcloud.com/) -> Support -> Third-party Ecology (old site) or Service -> API (new site), enter the value of `tokenID` here (Example: 20241028488283838)
serial: # Serial number, [solaxcloud.com](https://www.solaxcloud.com/) -> Device -> Inverter (new site) or Support (old site), use the registration number
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)