Aller au contenu
recharge intelligente

E3/DC

The communication is done locally. evcc must be in the same network as the E3/DC system.

Note: Active battery control will override Smart-Power/Operating Range settings.

Fonctionnalités prises en charge

  • Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie

Paramètres

NomDescriptionValeurNiveau
hostIP address or hostname
Exemple: 192.0.2.2
facultatif
userUsername

Identical with Web Portal or E3/DC App.

facultatif
passwordPassword

Identical with Web Portal or E3/DC App.

facultatif
keyRSCP password

Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.

facultatif
portPort
Par défaut: 5033
facultatif
capacity [kWh]Battery capacity
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Par défaut: 100
Exemple: 95
facultatif
maxacpower [W]Maximum AC power of the hybrid inverter
Par défaut: 0
Exemple: 5000
avancé
externalpowerInclude external power

Includes all connected external sources into the PV calculation (default).

Par défaut: true
avancé
dischargelimitDischarge limit in W

Limits discharge power in 'Hold' battery mode

avancé
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avancé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: e3dc-rscp
usage: grid
host: 192.0.2.2 # IP address or hostname
user: # Username, Identical with Web Portal or E3/DC App.
password: # Password, Identical with Web Portal or E3/DC App.
key: # RSCP password, Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.
port: 5033 # Port, optional
meters:
- name: my_pv
type: template
template: e3dc-rscp
usage: pv
host: 192.0.2.2 # IP address or hostname
user: # Username, Identical with Web Portal or E3/DC App.
password: # Password, Identical with Web Portal or E3/DC App.
key: # RSCP password, Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.
port: 5033 # Port, optional
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
externalpower: true # Include external power, Includes all connected external sources into the PV calculation (default). (optional)
meters:
- name: my_battery
type: template
template: e3dc-rscp
usage: battery
host: 192.0.2.2 # IP address or hostname
user: # Username, Identical with Web Portal or E3/DC App.
password: # Password, Identical with Web Portal or E3/DC App.
key: # RSCP password, Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.
port: 5033 # Port, optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
dischargelimit: # Discharge limit in W, Limits discharge power in 'Hold' battery mode (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)