The communication is done locally. evcc must be in the same network as the E3/DC system.

Note: Active battery control will override Smart-Power/Operating Range settings.

Fonctionnalités prises en charge

  • Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie

Paramètres

NomDescriptionValeurNiveau
hostIP address or hostname
Exemple: 192.0.2.2
facultatif
userUsername

Identical with Web Portal or E3/DC App.

facultatif
passwordPassword

Identical with Web Portal or E3/DC App.

facultatif
keyRSCP password

Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.

facultatif
portPort
Par défaut: 5033
facultatif
capacity [kWh]Battery capacity
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Par défaut: 100
Exemple: 95
facultatif
maxacpower [W]Maximum AC power of the hybrid inverter
Par défaut: 0
Exemple: 5000
avancé
externalpowerInclude external power

Includes all connected external sources into the PV calculation (default).

Par défaut: true
avancé
dischargelimitDischarge limit in W

Limits discharge power in 'Hold' battery mode

avancé
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avancé
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: e3dc-rscp
usage: grid
host: 192.0.2.2 # IP address or hostname
user: # Username, Identical with Web Portal or E3/DC App.
password: # Password, Identical with Web Portal or E3/DC App.
key: # RSCP password, Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.
port: 5033 # Port, optional
meters:
- name: my_pv
type: template
template: e3dc-rscp
usage: pv
host: 192.0.2.2 # IP address or hostname
user: # Username, Identical with Web Portal or E3/DC App.
password: # Password, Identical with Web Portal or E3/DC App.
key: # RSCP password, Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.
port: 5033 # Port, optional
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
externalpower: true # Include external power, Includes all connected external sources into the PV calculation (default). (optional)
meters:
- name: my_battery
type: template
template: e3dc-rscp
usage: battery
host: 192.0.2.2 # IP address or hostname
user: # Username, Identical with Web Portal or E3/DC App.
password: # Password, Identical with Web Portal or E3/DC App.
key: # RSCP password, Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.
port: 5033 # Port, optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
dischargelimit: # Discharge limit in W, Limits discharge power in 'Hold' battery mode (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)