Sonnen sonnenBatterie

For active battery control, the "JSON Write API" must be activated via the sonnenBatterie web interface (under Software-Integration) and the API token generated there must be entered in the battery configuration under token. The two operating modes supported for the sonnenBatterie are "self-consumption" (default) and "time-of-use". The mode can be adapted to the configuration of the sonnenBatterie via the 'defaultmode' parameter. The power for grid charging can be adapted to the inverter power of the sonnenBatterie via the maxchargepower parameter.

Fonctionnalités prises en charge

  • Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie

Paramètres

NomDescriptionValeurNiveau
hostIP address or hostname
Exemple: 192.0.2.2
facultatif
defaultmodeDefault mode for battery control

Inverter falls back to this mode after charging the battery or after stopping discharge.

Par défaut: self-consumption
facultatif
portPort
Par défaut: 8080
facultatif
capacity [kWh]Battery capacity
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Par défaut: 100
Exemple: 95
facultatif
tokenToken

API Token (required for active battery control)

facultatif
maxchargepower [W]Maximum charge power

For forced charging of the battery.

Par défaut: 3300
avancé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avancé
cacheCache

Time interval for data refresh

Par défaut: 1s
Exemple: 5m
avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: sonnenbatterie
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 8080 # Port, optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: sonnenbatterie
usage: pv
host: 192.0.2.2 # IP address or hostname
port: 8080 # Port, optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: sonnenbatterie
usage: battery
host: 192.0.2.2 # IP address or hostname
defaultmode: self-consumption # Default mode for battery control, Inverter falls back to this mode after charging the battery or after stopping discharge. [self-consumption, time-of-use]
port: 8080 # Port, optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
token: # Token, API Token (required for active battery control) (optional)
maxchargepower: 3300 # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)