The rest-api adapter (not simple-api) must be installed on the ioBroker instance being used. It can be configured stand-alone or as an extension of a web adapter. The parameter webextension determines whether the adapter is configured as a web extension. Default is true, which means that the adapter is configured as a web extension. Authentication can only be performed using basic authentication. If no password is provided, no authentication will be performed. When specifying the entities for the individual measured values, ensure that they are correctly URL-encoded. For example, shelly.0.SHEM-3#8CAAB561991E#1.Total.ConsumedPower becomes shelly.0.SHEM-3%238CAAB561991E%231.Total.ConsumedPower

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie
  • Compteur du chargeur

Paramètres

NomDescriptionValeurNiveau
uriThe full uri of the host to query

HTTP(S) address

Exemple: https://iobroker.homelab.lan:8082
facultatif
webextensionRest as web extension

Determines whether the REST adapter is installed stand alone or as a web extension. Should 404 errors occur, try changing the value.

Par défaut: true
facultatif
userUsername

e.g. email address, user id, etc.

facultatif
passwordPassword

Service account password

facultatif
power [W]Powerfacultatif
soc [%]State of Chargefacultatif
capacity [kWh]Battery capacity
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Par défaut: 100
Exemple: 95
facultatif
cacheCache

Time interval for data refresh

Exemple: 5m
avancé
energy [kWh]Meter readingavancé
currentL1 [A]L1 currentavancé
currentL2 [A]L2 currentavancé
currentL3 [A]L3 currentavancé
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avancé
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avancé
maxacpower [W]Maximum AC power of the hybrid inverter
Par défaut: 0
Exemple: 5000
avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: iobroker
usage: grid
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
webextension: true # Rest as web extension, Determines whether the REST adapter is installed stand alone or as a web extension. Should 404 errors occur, try changing the value. (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional
meters:
- name: my_pv
type: template
template: iobroker
usage: pv
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
webextension: true # Rest as web extension, Determines whether the REST adapter is installed stand alone or as a web extension. Should 404 errors occur, try changing the value. (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
meters:
- name: my_battery
type: template
template: iobroker
usage: battery
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
webextension: true # Rest as web extension, Determines whether the REST adapter is installed stand alone or as a web extension. Should 404 errors occur, try changing the value. (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
meters:
- name: my_charger
type: template
template: iobroker
usage: charge
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
webextension: true # Rest as web extension, Determines whether the REST adapter is installed stand alone or as a web extension. Should 404 errors occur, try changing the value. (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional