SunEnergyXT SunEnergyXT 500 / 500 PRO
The battery's local mode must be enabled in the manufacturer's app.
Furthermore, the device's IP address must be set to a fixed, permanent IP address in the router.
An external meter (e.g., Shelly) measuring the grid connection point must be connected to the battery via the manufacturer's app.
It is required for the grid usage, and also for the battery usage, because the normal battery mode enables the device's
zero feed-in regulation, which reads this meter.
Fonctionnalités prises en charge
- Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.
Domaines d’utilisation
- Compteur avant réseau
- Production solaire
- Batterie
Paramètres
| Nom | Description | Valeur | Niveau |
|---|---|---|---|
model | Model
| facultatif | |
host | IP address or hostname | facultatif | |
capacity [kWh] | Battery capacity Total storage capacity: head unit 5 kWh, each extension pack adds 5 kWh. So 5 (head unit only), 10 (+1 extension) or 15 (+2 extensions). The number of detected battery packs is reported in the | facultatif | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facultatif | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | facultatif | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avancé | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | avancé | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | avancé | |
cache | Cache Time interval for data refresh | avancé | |
timeout | Timeout | avancé |
Exemple de configuration pour evcc.yaml
Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.
meters: - name: my_grid type: template template: sunenergyxt-500 usage: grid model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro] host: 192.0.2.2 # IP address or hostname cache: 2s # Cache, Time interval for data refresh (optional) timeout: 10s # Timeout, optionalmeters: - name: my_pv type: template template: sunenergyxt-500 usage: pv model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro] host: 192.0.2.2 # IP address or hostname maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional cache: 2s # Cache, Time interval for data refresh (optional) timeout: 10s # Timeout, optionalmeters: - name: my_battery type: template template: sunenergyxt-500 usage: battery model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro] host: 192.0.2.2 # IP address or hostname capacity: 5 # Battery capacity (kWh), Total storage capacity: head unit 5 kWh, each extension pack adds 5 kWh. So 5 (head unit only), 10 (+1 extension) or 15 (+2 extensions). The number of detected battery packs is reported in the `ON` field of `/read`. (optional) minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) maxchargepower: 2400 # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional) cache: 2s # Cache, Time interval for data refresh (optional) timeout: 10s # Timeout, optional